50L Neocision ETL Lab Certified Rotary Evaporator Turnkey System

★★★★★ 4.6 130 reviews

US$4,676.51
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by whatgoesonmedia.cleverpig.co.uk
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$4,676.51
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Jul 24
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by whatgoesonmedia.cleverpig.co.uk
Free 30-day returns Details

Product details

Management number 232367792 Release Date 2026/06/21 List Price US$4,676.51 Model Number 232367792
Category

50L Neocision ETL Lab Certified Rotary Evaporator Turnkey System

50L NEO Rotary Evaporator Turnkey System setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors.

Rotovap Flow Chart

50L NEO Rotary Evaporator Turnkey System setup includes:

This guide gives basic quick start instructions for rotovaps. It is intended to provide a starting point for learning the process. Parameters should be adjusted to suit specific needs.

  • Clean and assemble unit. Make sure all pieces are cleaned and sterilized using an alcohol solution.
  •  Connect chiller to condenser and set to 0C (32F). Always fill a rotovap condenser from the top down (chiller output to top of condenser, chiller input to bottom of condenser).
  •  Connect vacuum pump to cold trap and connect cold trap to vacuum port on rotovap.
  •  Turn on heat bath and set to 40C (113F).
  •  Once heat bath, chiller and cold trap have reached desired temperatures, turn on rotovap motor and set speed to approximately 100 RPM (does not have to be precise). Keep in mind, higher RPM’s will increase evaporation power but also increase heat load.
  •  Start vacuum pump and allow vacuum to pull down for a few minutes before injection.
  •  Once vacuum has been pulled to a sufficient level (does not have to be precise but should be below 100 Torr), using the injection valve, very slowly inject approximately 500 mL of solution into evaporating flask and then close the valve. Allow this small amount to begin evaporating. You may see the chiller begin to rise in temperature, this is called “priming” the rotovap.
  •  Once the temperature stops rising or all liquid is almost completely evaporated, open the injection valve again very slowly so that a small amount of liquid begins to enter the evaporating flask. Do not close injection valve this time but continue to allow solution to enter the evaporating flask.
  •  At this point you must try to match the input speed to the output speed. What this means is that you should be injecting the same amount of liquid into the rotovap that is equal to the amount of liquid dripping from the condenser into the receiving flask. You will know that the input speed and output speed are matched because the chiller will remain at a stable temperature. If the chiller begins to rise, then you are injecting too much liquid. Dial back the valve until the chiller stabilizes.
  •  Once everything is stabilized, you may walk away from the rotovap if necessary. Check every so often to make sure temperatures remain stable and evaporation continues efficiently.


Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.6 out of 5
★★★★★
130 ratings | 53 reviews
How item rating is calculated
View all reviews
5 stars
84% (109)
4 stars
3% (4)
3 stars
2% (3)
2 stars
1% (1)
1 star
10% (13)
Sort by

There are currently no written reviews for this product.